HNAS 4060
|
HNAS 4080
|
HNAS 4100
|
|---|---|---|---|
|
Protocol Support
|
HNAS 4060
NFS, SMB, FTP, iSCSI and HTTPS (S3) to the cloud
|
HNAS 4080
NFS, SMB, FTP, iSCSI and HTTPS (S3) to the cloud
|
HNAS 4100
NFS, SMB, FTP, iSCSI and HTTPS (S3) to the cloud
|
|
Max. EVS (Enterprise Virtual Servers)
|
HNAS 4060
64
|
HNAS 4080
64
|
HNAS 4100
64
|
|
Max. File Systems
|
HNAS 4060
500
|
HNAS 4080
500
|
HNAS 4100
500
|
|
Max. Virtual File System Size (with tiering to Object Store)
|
HNAS 4060
Unlimited up to max. files per file system
|
HNAS 4080
Unlimited up to max. files per file system
|
HNAS 4100
Unlimited up to max. files per file system
|
|
Max. Physical File System Size per Cluster
|
HNAS 4060
8PB
|
HNAS 4080
16PB
|
HNAS 4100
32PB
|
|
Max. Physical File System Size
|
HNAS 4060
1PB
|
HNAS 4080
1PB
|
HNAS 4100
1PB
|
|
Max. Files per File System
|
HNAS 4060
130 Billion
|
HNAS 4080
130 Billion
|
HNAS 4100
130 Billion
|
|
Max. File Size
|
HNAS 4060
256TB
|
HNAS 4080
256TB
|
HNAS 4100
256TB
|
|
Throughput (Read, Write)
|
HNAS 4060
1GB/s, 1GB/s
|
HNAS 4080
1.5GB/s, 1.5GB/s
|
HNAS 4100
2GB/s, .5GB/s
|
|
Max. Logical Units (LUNs)
|
HNAS 4060
512
|
HNAS 4080
512
|
HNAS 4100
512
|
|
Max. LUN Size
|
HNAS 4060
64TB
|
HNAS 4080
64TB
|
HNAS 4100
64TB
|
|
Max. Mount Points (Shares and Exports)
|
HNAS 4060
20,000 shares, 10,000 exports.
Note: Maximum tested configurations are: a) 10k exports with 10k shares, or b) 5k exports with 20k shares |
HNAS 4080
20,000 shares, 10,000 exports.
Note: Maximum tested configurations are: a) 10k exports with 10k shares, or b) 5k exports with 20k shares |
HNAS 4100
20,000 shares, 10,000 exports.
Note: Maximum tested configurations are: a) 10k exports with 10k shares, or b) 5k exports with 20k shares |
|
Max. Connections (NFS/SMB)
|
HNAS 4060
45,000
|
HNAS 4080
45,000
|
HNAS 4100
45,000
|
|
Max. Concurrent Open Files per Node: SMB
|
HNAS 4060
227,000
|
HNAS 4080
227,000
|
HNAS 4100
1,178,000
|
|
Max. Concurrent FTP Sessions
|
HNAS 4060
10,000
|
HNAS 4080
10,000
|
HNAS 4100
10,000
|
|
SMB/NFS File Name Length
|
HNAS 4060
255 Characters
|
HNAS 4080
255 Characters
|
HNAS 4100
255 Characters
|
|
SMB Path Name Length
|
HNAS 4060
65,535 Characters
|
HNAS 4080
65,535 Characters
|
HNAS 4100
65,535 Characters
|
|
NFS Path Name Length
|
HNAS 4060
1,024 Characters
|
HNAS 4080
1,024 Characters
|
HNAS 4100
1,024 Characters
|
|
iSCSI Targets per EVS
|
HNAS 4060
32
|
HNAS 4080
32
|
HNAS 4100
32
|
|
iSCSI LUNs per Target
|
HNAS 4060
32
|
HNAS 4080
32
|
HNAS 4100
32
|
|
iSCSI Sessions per Target
|
HNAS 4060
64
|
HNAS 4080
64
|
HNAS 4100
64
|
|
iSCSI LUN Size
|
HNAS 4060
256TB
|
HNAS 4080
256TB
|
HNAS 4100
256TB
|
|
Max. VLANS
|
HNAS 4060
256
|
HNAS 4080
256
|
HNAS 4100
256
|
|
Rack Height
|
HNAS 4060
3U
|
HNAS 4080
3U
|
HNAS 4100
3U
|
|
Power Supply
|
HNAS 4060
Dual
|
HNAS 4080
Dual
|
HNAS 4100
Dual
|
|
Memory on Main FPGA Board (MFB)
|
HNAS 4060
26GB/4GB NVRAM
|
HNAS 4080
26GB/4GB NVRAM
|
HNAS 4100
68GB/8GB NVRAM
|
|
Memory on Main Motherboard (MMB)
|
HNAS 4060
16GB
|
HNAS 4080
16GB
|
HNAS 4100
32GB
|
|
Random I/O: Dual-Node
|
HNAS 4060
147,957
|
HNAS 4080
209,519
|
HNAS 4100
293,128
|
|
Throughput: MB/s (mixed workloads 75/25 read/write) per Node
|
HNAS 4060
1,000
|
HNAS 4080
1,500
|
HNAS 4100
2,000
|
|
Cooling Fans
|
HNAS 4060
2 – Hot Swap
|
HNAS 4080
2 – Hot Swap
|
HNAS 4100
2 – Hot Swap
|
|
Power Supplies
|
HNAS 4060
2 – Hot Swap
|
HNAS 4080
2 – Hot Swap
|
HNAS 4100
2 – Hot Swap
|
|
10GbE LAN Ports
|
HNAS 4060
4
|
HNAS 4080
4
|
HNAS 4100
4
|
|
Fibre Channel Storage Ports
|
HNAS 4060
4
|
HNAS 4080
4
|
HNAS 4100
4
|
|
Voltage Range
|
HNAS 4060
100 VAC – 3.5A
110 VAC – 3.2A 200 VAC – 1.8A 208 VAC – 1.7A 240 VAC – 1.5A |
HNAS 4080
100 VAC – 3.5A
110 VAC – 3.2A 200 VAC – 1.8A 208 VAC – 1.7A 240 VAC – 1.5A |
HNAS 4100
100 VAC – 3.5A
110 VAC – 3.2A 200 VAC – 1.8A 208 VAC – 1.7A 240 VAC – 1.5A |
|
Power Supply Rating
|
HNAS 4060
550W
|
HNAS 4080
550W
|
HNAS 4100
550W
|
|
Average Thermal (BTU/hour)
|
HNAS 4060
888
|
HNAS 4080
888
|
HNAS 4100
888
|
|
Max. Thermal (BTU/hour)
|
HNAS 4060
1194
|
HNAS 4080
1194
|
HNAS 4100
1194
|
|
Max. Power Usage
|
HNAS 4060
350W
|
HNAS 4080
350W
|
HNAS 4100
350W
|
|
Height/Width/Depth
|
HNAS 4060
3U, 5.1 in. (130mm)/
17.2 in. (437mm)/27 in. (685mm) |
HNAS 4080
3U, 5.1 in. (130mm)/
17.2 in. (437mm)/27 in. (685mm) |
HNAS 4100
3U, 5.1 in. (130mm)/
17.2 in. (437mm)/27 in. (685mm) |
|
Weight
|
HNAS 4060
55 lbs. (25kg)
|
HNAS 4080
55 lbs. (25kg)
|
HNAS 4100
55 lbs. (25kg)
|
|
Compliance
|
HNAS 4060
RoHS 6
China RoHS Labeled Safety EU: EN 60950-1, Low Voltage 73/23/EEC Canada: CSA 60950-1 US: UL 60950-1 EMC EU: 55022 Class A, 55024, EN61000 US: FCC Part 15 Subpart B, Class A Japan: VDDI Class A |
HNAS 4080
RoHS 6
China RoHS Labeled Safety EU: EN 60950-1, Low Voltage 73/23/EEC Canada: CSA 60950-1 US: UL 60950-1; EMC EU: 55022 Class A, 55024, EN61000 US: FCC Part 15 Subpart B, Class A Japan: VDDI Class A |
HNAS 4100
RoHS 6
China RoHS Labeled Safety EU: EN 60950-1, Low Voltage 73/23/EEC Canada: CSA 60950-1 US: UL 60950-1; EMC EU: 55022 Class A, 55024, EN61000 US: FCC Part 15 Subpart B, Class A Japan: VDDI Class A |