VSP N400
|
VSP N600
|
VSP N800
|
|---|---|---|---|
|
Protocols
|
VSP N400
NFS, SMB, FTP, iSCSI and HTTPS to the cloud
|
VSP N600
NFS, SMB, FTP, iSCSI and HTTPS to the cloud
|
VSP N800
NFS, SMB, FTP, iSCSI and HTTPS to the cloud
|
|
Max. EVS (Enterprise Virtual Servers)
|
VSP N400
64
|
VSP N600
64
|
VSP N800
64
|
|
Max. File Systems
|
VSP N400
500
|
VSP N600
500
|
VSP N800
500
|
|
Max. Virtual File System Size (with tiering to Object Store)
|
VSP N400
Unlimited up to max. files per file system
|
VSP N600
Unlimited up to max. files per file system
|
VSP N800
Unlimited up to max. files per file system
|
|
Max. Physical File System Size per System
|
VSP N400
2PB
|
VSP N600
6.5PB
|
VSP N800
6.5PB
|
|
Max. Physical File System Size
|
VSP N400
1PB
|
VSP N600
1PB
|
VSP N800
1PB
|
|
Max. Files per File System
|
VSP N400
130 Billion
|
VSP N600
130 Billion
|
VSP N800
130 Billion
|
|
Max. File Size
|
VSP N400
256TB
|
VSP N600
256TB
|
VSP N800
256TB
|
|
Throughput (Read, Write)
|
VSP N400
3GB/s, 1.5GB/s
|
VSP N600
4GB/s, 2GB/s
|
VSP N800
8.4GB/s, 3.1GB/s
|
|
Number of VLANs
|
VSP N400
4, 095
|
VSP N600
4, 095
|
VSP N800
4, 095
|
|
Max. IP Addresses per Cluster
|
VSP N400
256
|
VSP N600
256
|
VSP N800
256
|
|
Max. IP Addresses per EVS
|
VSP N400
32
|
VSP N600
32
|
VSP N800
32
|
|
Max. Snapshots per File System
|
VSP N400
1,024
|
VSP N600
1,024
|
VSP N800
1,024
|
|
Max. Global Symlinks
|
VSP N400
10,000
|
VSP N600
10,000
|
VSP N800
10,000
|
|
Max. CNS Links
|
VSP N400
500
|
VSP N600
500
|
VSP N800
500
|
|
Max. Mount Points (Shares and Exports)
|
VSP N400
20,000 shares, 10,000 exports. Note: Maximum tested configurations are:a) 10k exports with 10k shares, or b) 5k exports with 20k shares
|
VSP N600
20,000 shares, 10,000 exports. Note: Maximum tested configurations are:a) 10k exports with 10k shares, or b) 5k exports with 20k shares
|
VSP N800
20,000 shares, 10,000 exports. Note: Maximum tested configurations are:a) 10k exports with 10k shares, or b) 5k exports with 20k shares
|
|
Max. Concurrent NFS and/or SMB Clients
|
VSP N400
64,000
|
VSP N600
64,000
|
VSP N800
64,000
|
|
Max. Virtual Volumes
|
VSP N400
100,000
|
VSP N600
100,000
|
VSP N800
100,000
|
|
Max. User or Group Quotas
|
VSP N400
100,000
|
VSP N600
100,000
|
VSP N800
100,000
|
|
Max. Concurrent Open Files: SMB
|
VSP N400
1,178,000
|
VSP N600
1,500,000
|
VSP N800
1,500,000
|
|
Max. NAS SD/LUN size
|
VSP N400
64TB
|
VSP N600
64TB
|
VSP N800
64TB
|
|
Max. NAS System Drives
|
VSP N400
512
|
VSP N600
512
|
VSP N800
512
|
|
HARDWARE SPECIFICATIONS
|
-
|
-
|
-
|
|
10Gb/s Client Ports per NAS module
|
VSP N400
6
|
VSP N600
6
|
VSP N800
6
|
|
Host Interface Types
|
VSP N400
FC: 32Gb/s
FC: 16Gb/s FC: 8Gb/s iSCSI: 10Gb/s |
VSP N600
FC: 32Gb/s
FC: 16Gb/s FC: 8Gb/s iSCSI: 10Gb/s |
VSP N800
FC: 32Gb/s
FC: 16Gb/s FC: 8Gb/s iSCSI: 10Gb/s |
|
Host Port Counts
|
VSP N400
24 x FC
12 x iSCSI |
VSP N600
24 x FC
12 x iSCSI |
VSP N800
32 x FC
16 x iSCSI |
|
NAS Module Memory
|
VSP N400
96GiB (8GiB NVRAM) per NAS module
|
VSP N600
96GiB (8GiB NVRAM) per NAS module
|
VSP N800
96GiB (8GiB NVRAM) per NAS module
|
|
Modules per Cluster
|
VSP N400
Two NAS modules internal to each VSP N400
|
VSP N600
Two NAS modules internal to each VSP N600
|
VSP N800
Two NAS modules internal to each VSP N800
|
|
Max. Controller Cache
|
VSP N400
128GiB
|
VSP N600
256GiB
|
VSP N800
512GiB
|
|
Max. Flash Drives, Including Spares
|
VSP N400
384 SSD
192 FMD |
VSP N600
576 SSD
288 FMD |
VSP N800
1,152 SSD
576 FMD |
|
Max. Hard Drives, Including Spares
|
VSP N400
384 SFF
480 LFF |
VSP N600
576 SFF
720 LFF |
VSP N800
1,152 SFF
1,440 LFF |
|
Max. Raw Internal Capacity
|
VSP N400
4,699TB (10TB LFF HDD)
885TB (2.4TB SFF HDD) 2,702TB (14TB FMD) 2,903TB (7.6TB SSD) |
VSP N600
7,049TB (10TB LFF HDD)
1,328TB (2.4TB SFF HDD) 4,053TB (14TB FMD) 4,355TB (7.6TB SSD) |
VSP N800
14,098TB (10TB LFF HDD)
2,656TB (2.4TB SFF HDD) 8,106TB (14TB FMD) 8,711TB (7.6TB SSD) |
|
Flash Drive Options
|
VSP N400
14TB FMD
7TB FMD 7.6TB 2.5” SSD 3.8TB 2.5” SSD 1.9TB 2.5” SSD |
VSP N600
14TB FMD
7TB FMD 7.6TB 2.5” SSD 3.8TB 2.5” SSD 1.9TB 2.5” SSD |
VSP N800
14TB FMD
7TB FMD 7.6TB 2.5” SSD 3.8TB 2.5” SSD 1.9TB 2.5” SSD |
|
SAS Hard Drive Options
|
VSP N400
10TB (3.5” 7.2K)
6TB (3.5” 7.2K) 2.4TB (2.5” 10K) 1.2TB (2.5” 10K) 600GB (2.5” 10K) |
VSP N600
10TB (3.5” 7.2K)
6TB (3.5” 7.2K) 2.4TB (2.5” 10K) 1.2TB (2.5” 10K) 600GB (2.5” 10K) |
VSP N800
10TB (3.5” 7.2K)
6TB (3.5” 7.2K) 2.4TB (2.5” 10K) 1.2TB (2.5” 10K) 600GB (2.5” 10K) |
|
Max. Standard Expansion Trays
|
VSP N400
16 (2U: 12 LFF)
16 (2U: 24 SFF/SSD) |
VSP N600
24 (2U: 12 LFF)
24 (2U: 24 SFF/SSD) |
VSP N800
48 (2U: 12 LFF)
48 (2U: 24 SFF/SSD) |
|
Max. High Density Expansion Trays
|
VSP N400
8 (4U: 60 LFF)
|
VSP N600
12 (4U: 60 LFF)
|
VSP N800
24 (4U: 60 LFF)
|
|
Max. Flash Module Expansion Trays
|
VSP N400
16 (2U: 12 FMD)
|
VSP N600
24 (2U: 12 FMD)
|
VSP N800
48 (2U: 12 FMD)
|
|
Height Width Depth
|
VSP N400
4U, 6.9" (174mm)
19.0" (483mm) 35.1” (892mm) |
VSP N600
4U, 6.9" (174mm)
19.0" (483mm) 35.1” (892mm) |
VSP N800
4U, 6.9" (174mm)
19.0" (483mm) 35.1” (892mm) |
|
Max. Controller Weight
|
VSP N400
187 lbs. (85kg)
|
VSP N600
187 lbs. (85kg)
|
VSP N800
187 lbs. (85kg)
|
|
Fibre Bandwidth to Host
|
VSP N400
76,800MB/s
|
VSP N600
76,800MB/s
|
VSP N800
102,400MB/s
|
|
Back-End Disk Interface and Links
|
VSP N400
16 x 12Gb/s SAS
|
VSP N600
16 x 12Gb/s SAS
|
VSP N800
64 x 12Gb/s SAS
|
|
SVOS SPECIFICATIONS
|
-
|
-
|
-
|
|
RAID Supported
|
VSP N400
RAID-1, RAID-5, RAID-6
|
VSP N600
RAID-1, RAID-5, RAID-6
|
VSP N800
RAID-1, RAID-5, RAID-6
|
|
Data-at-Rest Encryption
|
VSP N400
Yes
|
VSP N600
Yes
|
VSP N800
Yes
|
|
Max. LUN Size
|
VSP N400
256TB
|
VSP N600
256TB
|
VSP N800
256TB
|
|
Max. LUNs
|
VSP N400
4,096
|
VSP N600
4,096
|
VSP N800
16,384
|
|
Max. Snapshots
|
VSP N400
1,024 per LUN;
102,400 per system |
VSP N600
1,024 per LUN;
102,400 per system |
VSP N800
1,024 per LUN;
102,400 per system |
|
Max. Hosts per Fibre Channel Port
|
VSP N400
255
|
VSP N600
255
|
VSP N800
255
|
|
Notes: |