Specification | Hitachi Vantara
HNAS 5200
Protocol Support NFS, SMB, FTP, iSCSI and HTTPS(S3) to the cloud
Virtual Cluster Support Up to 40 nodes
Aggregate Performance (GB/s) 192
Max. Virtual File System/Namespace Size (w/tiering to Object Store) Unlimited up to max. files per file system/namespace
Max. Files per File System/Namespace 130/840 Billion
Max. Mount Points (Shares and Exports)
Note: Maximum tested configurations are: a) 10k exports with 10k shares, or b) 5k exports with 20k shares
20,000 shares, 10,000 exports. 
Max. Connections (NFS/SMB) 64,000
Max. Concurrent Open Files per Node: SMB 1.65 million
Max. Nodes per Namespace Up to 4
Max. File Systems per Namespace 500
Max. File System Capacity per Namespace 16PB
Max. File System Size 1PB
Max. EVS (Enterprise Virtual Servers) per Namespace 64
Max. Logical Units (LUNs) 512
Max. LUN Size 64TB
Max. Concurrent FTP Sessions 10000
SMB/NFS File Name Length 255 Characters
SMB Path Name Length 65,535 Characters
NFS Path Name Length 1024 Characters
iSCSI Targets per EVS 32
iSCSI LUNs per Target 32
iSCSI Sessions per Target 64
iSCSI LUN Size 256TB
Max. VLANS 4095
Rack Unit Height 3U
Power Supply Dual
Memory on FPGA Board 96GB/16GB NVRAM 
Memory on Motherboard 64GB
Random I/O: per Node 87500
Throughput: MB/sec (Read) per Node 3,400
Throughput: MB/sec (Write) per Node 1,300
Throughput: MB/sec (mixed workloads 70/30 read/write) per Node 3400
Cooling Fans 2 – Hot Swap
Power Supplies 2 – Hot Swap
10GbE LAN Ports 6
FC Storage Ports 4
Voltage Range (Ave/Max) 100 VAC – 2.1/2.6A
110 VAC – 1.9/2.4A
200 VAC – 1.0/1.3A
208 VAC – 1.0/1.3A
230 VAC – 0.9/1.2A
Power Supply Rating 495W
Average Thermal (BTU/hour) 710
Max. Thermal (BTU/hour) 887
Max. Power Usage 260W
Height/Width/Depth 3U, 5.2 in. (132mm)/
17.3 in. (440mm)/28.6 in. (725mm)
Weight 51 lbs. (23kg)
Compliance RoHS 6
China RoHS Compliant
EU RoHS Compliant
Safety
EU: EN62368-1: 2nd edition
Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition
US: UL 62368-1
EMC
EU: EN62368-1: 2nd edition
Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition
US: UL 62368-1
HNAS 5300
Protocol Support NFS, SMB, FTP, iSCSI and HTTPS(S3) to the cloud
Virtual Cluster Support Up to 80 nodes
Aggregate Performance (GB/s) 384
Max. Virtual File System/Namespace Size (w/tiering to Object Store) Unlimited up to max. files per file system/namespace
Max. Files per File System/Namespace 130/840 Billion
Max. Mount Points (Shares and Exports)
Note: Maximum tested configurations are: a) 10k exports with 10k shares, or b) 5k exports with 20k shares
20,000 shares, 10,000 exports.
Max. Connections (NFS/SMB) 64,000
Max. Concurrent Open Files per Node: SMB 2.3 million
Max. Nodes per Namespace Up to 8
Max. File Systems per Namespace 500
Max. File System Capacity per Namespace 32PB
Max. File System Size 1PB
Max. EVS (Enterprise Virtual Servers) per Namespace 64
Max. Logical Units (LUNs) 512
Max. LUN Size 64TB
Max. Concurrent FTP Sessions 10000
SMB/NFS File Name Length 255 Characters
SMB Path Name Length 65,535 Characters
NFS Path Name Length 1024 Characters
iSCSI Targets per EVS 32
iSCSI LUNs per Target 32
iSCSI Sessions per Target 64
iSCSI LUN Size 256TB
Max. VLANS 4095
Rack Unit Height 3U
Power Supply Dual
Memory on FPGA Board 96GB/16GB NVRAM 
Memory on Motherboard 64GB
Random I/O: per Node 125,000
Throughput: MB/sec (Read) per Node 4,800
Throughput: MB/sec (Write) per Node 1,800
Throughput: MB/sec (mixed workloads 70/30 read/write) per Node 3,700
Cooling Fans 2 – Hot Swap
Power Supplies 2 – Hot Swap
10GbE LAN Ports 6
FC Storage Ports 4
Voltage Range (Ave/Max) 100 VAC – 2.1/2.6A
110 VAC – 1.9/2.4A
200 VAC – 1.0/1.3A
208 VAC – 1.0/1.3A
230 VAC – 0.9/1.2A
Power Supply Rating 495W
Average Thermal (BTU/hour) 710
Max. Thermal (BTU/hour) 887
Max. Power Usage 260W
Height/Width/Depth 3U, 5.2 in. (132mm)/
17.3 in. (440mm)/28.6 in. (725mm)
Weight 51 lbs. (23kg)
Compliance RoHS 6
China RoHS Compliant
EU RoHS Compliant
Safety
EU: EN62368-1: 2nd edition
Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition
US: UL 62368-1
EMC
EU: EN62368-1: 2nd edition
Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition
US: UL 62368-1
{ "FirstName": "First Name", "LastName": "Last Name", "Email": "Business Email", "Title": "Job Title", "Company": "Company Name", "Address": "Address", "City": "City", "State":"State", "Country":"Country", "Phone": "Business Telephone", "LeadCommentsExtended": "Additional Information(optional)", "LblCustomField1": "What solution area are you wanting to discuss?", "ApplicationModern": "Application Modernization", "InfrastructureModern": "Infrastructure Modernization", "Other": "Other", "DataModern": "Data Modernization", "GlobalOption": "If you select 'Yes' below, you consent to receive commercial communications by email in relation to Hitachi Vantara's products and services.", "GlobalOptionYes": "Yes", "GlobalOptionNo": "No", "Submit": "Submit", "EmailError": "Must be valid email.", "RequiredFieldError": "This field is required." }